Skip to end of metadata
Go to start of metadata
StatusEXECUTED
Stakeholders
Outcome
Due date 
OwnerThorsten Heinze 

Proposal

The MW Model shall not be amended by attributes for ODU Hardware and Firmware.
Corresponding attributes of the ONF Core IM shall be used.
Mantis issue#23 shall be closed without changes to the MW model.

Background

Content of the Mantis Bug Tracker:

DescriptionVersions of the ODU Hardware and Firmware shall be available for reading.
Notes
martin.skorupski
2017-10-04 15:40

My porposal is to use the ONF CoreModel, which includes equipment and the following information:

< manufactured-thing>
  <equipment-type>
    <version>p1.module</version>
    <description>WS/DS1</description>
    <part-type-identifier>part-number-s3s</part-type-identifier>
    <model-identifier>model-id-s3s</model-identifier>
    <type-name>p1.module_A</type-name>
  </equipment-type>
  <manufacturer-properties>
    <manufacturer-identifier>CIT</manufacturer-identifier>
  </manufacturer-properties>
  <equipment-instance>
    <manufacture-date>2007-08-27T00:00:00.0Z</manufacture-date>
    <serial-number>serial-number-s3s</serial-number>
  </equipment-instance>
< /manufactured-thing>

in case of missing information a conditional-package may helo: A first model can be found here: https://github.com/OpenNetworkingFoundation/CENTENNIAL/blob/master/models/yang/onf-core-model-conditional-packages.yang [^]